EV chargers · 2026 range
From the garage to the EV charging station: 3.7 to 600 kW.
Twenty chargers in four families: home AC, commercial AC, portable and DC fast charging, all manageable via OCPP. Plus the Storage Flow, with a built-in battery for fast charging without upgrading the grid connection.

- 3.7–22kW
- AC charging
- 40–600kW
- DC fast charging
- 500A
- Maximum current
- OCPP 1.6J
- Remote management
Home, commercial and portable
2 to 4 connectors
Liquid-cooled connectors (Dual Hyper Flow)
Upgradable to OCPP 2.0.1
The range
Twenty chargers, four families.
Filter by format or by the power you need. Each card links to its catalogue page.
20 models
Home ACHome Flow
7.4 · 22 kW
Home charger with Type 2 cable, mobile app and OCPP 1.6J.
- Outputs
- 1
- Protection
- IP65
Datasheet
- Output current
- 32 A
- Connectors
- 5 m Type 2 cable
- Display
- —
- Dimensions
- Packaging 48 × 27.2 × 33.5 cm
- Weight
- 7.5 kg packed
- Cooling
- —
- Installation
- Wall-mounted
Home ACHome Flow Socket
7.4 · 22 kW
Type 2 socket for use with the vehicle's own cable.
- Outputs
- 1
- Protection
- IP55
Datasheet
- Output current
- 32 A
- Connectors
- Type 2 socket
- Display
- —
- Dimensions
- Packaging 48 × 27.2 × 25.3 cm
- Weight
- 5.6 kg packed
- Cooling
- —
- Installation
- Wall-mounted
Home ACHome Flow 2
7.4 · 22 kW
Second-generation tethered home charger.
- Outputs
- 1
- Protection
- IP65
Datasheet
- Output current
- 32 A
- Connectors
- 5 m Type 2 cable
- Display
- —
- Dimensions
- Packaging 49.6 × 28.7 × 26 cm
- Weight
- 6.5 kg (22 kW) / 5.5 kg (7.4 kW) packed
- Cooling
- —
- Installation
- Wall-mounted
Commercial ACCity Flow
7.4 · 22 kW
MID meter, built-in RCD and 4G to run the charge point over OCPP.
- Outputs
- 1
- Protection
- IP65
Datasheet
- Output current
- 32 A
- Connectors
- 5 m Type 2 cable
- Display
- LCD 5"
- Dimensions
- Packaging 47 × 37.2 × 30.2 cm
- Weight
- 13.5 kg (22 kW) / 12.5 kg (7.4 kW) packed
- Cooling
- —
- Installation
- Wall-mounted
Commercial ACCity Flow Socket
7.4 · 22 kW
Type 2 socket version of the City Flow, with MID meter.
- Outputs
- 1
- Protection
- IP65
Datasheet
- Output current
- 32 A
- Connectors
- Type 2 socket
- Display
- LCD 5"
- Dimensions
- Packaging 47 × 37.2 × 22 cm
- Weight
- 11 kg (22 kW) / 10.5 kg (7.4 kW) packed
- Cooling
- —
- Installation
- Wall-mounted
Commercial ACDual City Flow
7.4 · 11 + 11 · 22 + 22 kW
Two vehicles at once from a single wall-mounted unit.
- Outputs
- 2
- Protection
- IP65
Datasheet
- Output current
- 32 + 32 A (22 kW) · 16 + 16 A (11 kW) · 32 A (7.4 kW)
- Connectors
- 2 × 5 m Type 2 cables
- Display
- LCD 5"
- Dimensions
- —
- Weight
- —
- Cooling
- —
- Installation
- Wall-mounted
Commercial ACDual Totem Flow
7.4 + 7.4 · 22 + 22 kW
Floor-standing pedestal with Type B RCD, MCB and surge protection.
- Outputs
- 2
- Protection
- IP65
Datasheet
- Output current
- 32 A per output
- Connectors
- 2 × 5 m Type 2 cables
- Display
- LCD 7"
- Dimensions
- —
- Weight
- —
- Cooling
- —
- Installation
- Floor-standing
Commercial ACDual Totem Flow Socket
7.4 + 7.4 · 22 + 22 kW
The pedestal with two Type 2 sockets and built-in protection.
- Outputs
- 2
- Protection
- IP65
Datasheet
- Output current
- 32 A per output
- Connectors
- 2 Type 2 sockets
- Display
- LCD 7"
- Dimensions
- —
- Weight
- —
- Cooling
- —
- Installation
- Floor-standing
PortableGo Flow
3.7 kW
Single-phase charger to keep in the car and plug in wherever you need it.
- Outputs
- 1
- Protection
- IP66
Datasheet
- Output current
- 8–16 A adjustable
- Connectors
- 6 m Type 2 cable + 1 m with 16 A Schuko plug
- Display
- —
- Dimensions
- Box of 4 units, 43.5 × 35 × 33 cm
- Weight
- 13.6 kg (box of 4)
- Cooling
- —
- Installation
- Portable
PortableGo Flow Compact
3.7 kW
All the electronics in the cable itself.
- Outputs
- 1
- Protection
- IP54
Datasheet
- Output current
- 6–16 A adjustable
- Connectors
- 5 m Type 2 cable with 16 A Schuko plug
- Display
- —
- Dimensions
- Box of 4 units, 48 × 41 × 36 cm
- Weight
- —
- Cooling
- —
- Installation
- Portable
PortableGo Flow Smart
7.4 · 11 · 22 kW
Portable with touchscreen and app, which can also be wall-mounted.
- Outputs
- 1
- Protection
- IP65
Datasheet
- Output current
- 6–32 A (11 kW: 6–16 A)
- Connectors
- 6 m Type 2 cable · industrial and domestic adapters
- Display
- 4.3" touchscreen
- Dimensions
- Packaging 50.5 × 50.5 × 17.5 cm
- Weight
- 9 kg packed
- Cooling
- —
- Installation
- Portable or wall-mounted
DC fast chargingDual Wall Flow
40 · 60 kW
Wall-mounted DC charging with two connectors, where a floor-standing unit won't fit.
- Outputs
- 2
- Protection
- IP55
Datasheet
- Output current
- 0–133 A
- Connectors
- 2 × CCS2
- Display
- 7" LCD touchscreen + LED
- Dimensions
- 705 × 735 × 330 mm (per catalogue)
- Weight
- 140 kg
- Cooling
- Forced air
- Installation
- Wall-mounted
DC fast chargingDual Flow
60 · 80 · 90 · 120 · 150 · 160 · 180 · 210 · 240 kW
Two vehicles at once, 60 to 240 kW, with a 21" screen.
- Outputs
- 2
- Protection
- IP55
Datasheet
- Output current
- 0–250 A
- Connectors
- 2 × CCS2
- Display
- 21" LCD touchscreen + LED
- Dimensions
- 800 × 800 × 1,800 mm
- Weight
- —
- Cooling
- Forced air
- Installation
- Floor-standing
DC fast chargingTriple Flow
120 · 150 kW
Three connector standards in one unit.
- Outputs
- 3
- Protection
- IP55
Datasheet
- Output current
- 0–250 A (CCS2)
- Connectors
- CCS2 + CCS1 + GB/T
- Display
- 21" LCD touchscreen + LED
- Dimensions
- 800 × 900 × 1,900 mm
- Weight
- —
- Cooling
- Forced air
- Installation
- Floor-standing
DC fast chargingQuad Flow
120 · 150 · 240 · 320 · 480 kW
Four connectors and up to 480 kW in a single unit.
- Outputs
- 4
- Protection
- IP55
Datasheet
- Output current
- 0–250 A (optional CHAdeMO 0–125 A)
- Connectors
- 120/150 kW: CCS2 + CCS1 + GB/T + Tesla · 240–480 kW: 4 × CCS2 · optional CHAdeMO
- Display
- 7" LCD touchscreen + LED
- Dimensions
- 800 × 900 × 1,900 mm
- Weight
- —
- Cooling
- Forced air
- Installation
- Floor-standing
DC fast chargingDual Power Flow
150 · 160 · 180 · 200 · 210 · 240 · 280 · 320 · 360 kW
Up to 360 kW and 350 A with integrated cable management.
- Outputs
- 2
- Protection
- IP55
Datasheet
- Output current
- 0–350 A (air-cooled connectors)
- Connectors
- 2 × CCS2
- Display
- 21" LCD touchscreen + LED
- Dimensions
- 800 × 800 × 1,950 mm
- Weight
- ≤ 480 kg
- Cooling
- Forced air
- Installation
- Floor-standing
DC fast chargingDual Hyper Flow
150 · 160 · 180 · 200 · 210 · 240 · 280 · 320 · 360 kW
The highest current in the range: 500 A per connector.
- Outputs
- 2
- Protection
- IP55
Datasheet
- Output current
- 0–500 A (liquid-cooled connectors)
- Connectors
- 2 × CCS2
- Display
- 21" LCD touchscreen + LED
- Dimensions
- 800 × 800 × 1,950 mm
- Weight
- ≤ 480 kg
- Cooling
- Forced air · liquid-cooled connectors
- Installation
- Floor-standing
DC fast chargingDual Media Flow
60 · 90 · 120 kW
43" touchscreen for advertising while charging.
- Outputs
- 2
- Protection
- IP55
Datasheet
- Output current
- 0–250 A
- Connectors
- 2 × CCS2
- Display
- 43" LCD touchscreen + LED
- Dimensions
- 700 × 520 × 1,800 mm
- Weight
- —
- Cooling
- Forced air
- Installation
- Floor-standing
DC fast chargingStorage Flow
80 kW · 42.5 kWh battery
Built-in battery for fast charging on low contracted power.
- Outputs
- 1
- Protection
- IP55
Datasheet
- Output current
- 0–200 A (300–1,000 V)
- Connectors
- CCS2
- Display
- 19" LCD touchscreen + LED
- Dimensions
- 880 × 1,160 × 2,100 mm
- Weight
- 740 kg
- Cooling
- Forced air
- Installation
- Floor-standing
DC fast chargingDual Satellite Flow
360 to 600 kW cabinet · up to 250 kW per dispenser
The power in one cabinet; the dispensers where vehicles park.
- Outputs
- 2 per dispenser
- Protection
- IP55
Datasheet
- Output current
- 0–250 A
- Connectors
- CCS2 + CCS2 per dispenser
- Display
- LCD 7" + LED
- Dimensions
- Cabinet 1,400 × 800 × 1,910 · dispenser 600 × 230 × 1,700 mm
- Weight
- Cabinet ≤ 800 kg · dispenser ≤ 110 kg
- Cooling
- Forced air
- Installation
- Floor-standing (split system)
No model matches that filter. Try another power rating.
Charging with a built-in battery
The battery supplies the peak. The grid connection only sees the average.
The Storage Flow has a built-in 42.5 kWh battery: it charges at 80 kW even when the grid connection falls short, and the battery recharges between sessions, during cheap hours or from solar PV.
- Charging power
- 80 kW · 1 CCS2 connector · 0–200 A
- Built-in battery
- 42.5 kWh
- Output voltage
- 300–1,000 V
- Display
- 19" LCD touchscreen + LED
- Dimensions and weight
- 880 × 1,160 × 2,100 mm · 740 kg
- Protection
- IP55 · forced air

BK integration
What we integrate into a charging point
A charger is only the beginning. We design the connection, the battery if needed, the software and the operation so that the charging point stays available and profitable.
- Integrated
- In the project
- Optional
- 01Integrated
Charger
AC from 3.7 to 22 kW or DC from 40 to 600 kW, wall-mounted, floor-standing or with satellite dispensers; CCS2 across all fast charging.
- 02Optional
Buffer battery
Storage Flow with 42.5 kWh built in, or a Power Pro next to the charging point, to charge at full power with a small grid connection.
- 03Integrated
OCPP 1.6J and connectivity
OCPP 1.6J (upgradable to 2.0.1) over Ethernet, 4G or WiFi for the management platform. RFID cards to authorise charging.
- 04Optional
BK EMS
EV charging mode with priorities and SOC limits: decides when to recharge the battery and how much to draw from the grid.
- 05In the project
Protection and grid connection
Main protection, earthing and engineering of the connection with the distribution network operator.
Comparison
The whole range in one table.
| Model | Power | Outputs | Current | Protection | Installation | Dimensions |
|---|---|---|---|---|---|---|
| Home Flow | 7.4 · 22 kW | 1 | 32 A | IP65 | Wall-mounted | Packaging 48 × 27.2 × 33.5 cm |
| Home Flow Socket | 7.4 · 22 kW | 1 | 32 A | IP55 | Wall-mounted | Packaging 48 × 27.2 × 25.3 cm |
| Home Flow 2 | 7.4 · 22 kW | 1 | 32 A | IP65 | Wall-mounted | Packaging 49.6 × 28.7 × 26 cm |
| City Flow | 7.4 · 22 kW | 1 | 32 A | IP65 | Wall-mounted | Packaging 47 × 37.2 × 30.2 cm |
| City Flow Socket | 7.4 · 22 kW | 1 | 32 A | IP65 | Wall-mounted | Packaging 47 × 37.2 × 22 cm |
| Dual City Flow | 7.4 · 11 + 11 · 22 + 22 kW | 2 | 32 + 32 A (22 kW) · 16 + 16 A (11 kW) · 32 A (7.4 kW) | IP65 | Wall-mounted | — |
| Dual Totem Flow | 7.4 + 7.4 · 22 + 22 kW | 2 | 32 A per output | IP65 | Floor-standing | — |
| Dual Totem Flow Socket | 7.4 + 7.4 · 22 + 22 kW | 2 | 32 A per output | IP65 | Floor-standing | — |
| Go Flow | 3.7 kW | 1 | 8–16 A adjustable | IP66 | Portable | Box of 4 units, 43.5 × 35 × 33 cm |
| Go Flow Compact | 3.7 kW | 1 | 6–16 A adjustable | IP54 | Portable | Box of 4 units, 48 × 41 × 36 cm |
| Go Flow Smart | 7.4 · 11 · 22 kW | 1 | 6–32 A (11 kW: 6–16 A) | IP65 | Portable or wall-mounted | Packaging 50.5 × 50.5 × 17.5 cm |
| Dual Wall Flow | 40 · 60 kW | 2 | 0–133 A | IP55 | Wall-mounted | 705 × 735 × 330 mm (per catalogue) |
| Dual Flow | 60 · 80 · 90 · 120 · 150 · 160 · 180 · 210 · 240 kW | 2 | 0–250 A | IP55 | Floor-standing | 800 × 800 × 1,800 mm |
| Triple Flow | 120 · 150 kW | 3 | 0–250 A (CCS2) | IP55 | Floor-standing | 800 × 900 × 1,900 mm |
| Quad Flow | 120 · 150 · 240 · 320 · 480 kW | 4 | 0–250 A (optional CHAdeMO 0–125 A) | IP55 | Floor-standing | 800 × 900 × 1,900 mm |
| Dual Power Flow | 150 · 160 · 180 · 200 · 210 · 240 · 280 · 320 · 360 kW | 2 | 0–350 A (air-cooled connectors) | IP55 | Floor-standing | 800 × 800 × 1,950 mm |
| Dual Hyper Flow | 150 · 160 · 180 · 200 · 210 · 240 · 280 · 320 · 360 kW | 2 | 0–500 A (liquid-cooled connectors) | IP55 | Floor-standing | 800 × 800 × 1,950 mm |
| Dual Media Flow | 60 · 90 · 120 kW | 2 | 0–250 A | IP55 | Floor-standing | 700 × 520 × 1,800 mm |
| Storage Flow | 80 kW · 42.5 kWh battery | 1 | 0–200 A (300–1,000 V) | IP55 | Floor-standing | 880 × 1,160 × 2,100 mm |
| Dual Satellite Flow | 360 to 600 kW cabinet · up to 250 kW per dispenser | 2 per dispenser | 0–250 A | IP55 | Floor-standing (split system) | Cabinet 1,400 × 800 × 1,910 · dispenser 600 × 230 × 1,700 mm |
Common to DC fast charging
- Output voltage
- 150–1,000 Vdc per CCS output (Storage Flow: 300–1,000 V; optional CHAdeMO on Quad Flow: 150–500 Vdc)
- Management
- OCPP 1.6J, upgradable to OCPP 2.0.1 · Ethernet, 4G and WiFi (Dual Satellite Flow: OCPP 1.6, Ethernet and 4G)
- Authorisation
- RFID cards included · emergency stop
- Cable
- 5 m
- Enclosure
- Carbon steel · indoor and outdoor use · IP55
- Environment
- −30…+55 °C (Dual Power, Dual Hyper and Dual Satellite Flow: −30…+50 °C)
- Standards
- IEC 61851-1 and IEC 61851-23; the Dual Satellite Flow also declares EN 61851-24, IEC 61851-21-2, IEC 61000-6-2 and EN 61000-6-4
Common to AC charging
- Power supply
- 230 V ±10% single-phase · 400 V ±10% three-phase · 50/60 Hz
- Connector
- Type 2, tethered or socket depending on model
- Management
- OCPP 1.6J; app via WiFi/Bluetooth on Home Flow and Go Flow Smart; 4G on City and Dual Totem Flow
- Protection
- RCD, MCB and surge protection built into Dual City and Dual Totem Flow; MID meter on City Flow
Applications
Where to install them
E-mobility
EV charging stations and service stations: Dual Power, Dual Hyper and Dual Satellite Flow, with the power in one cabinet and the dispensers where vehicles park.
E-mobility
Fleets and logistics: Dual, Triple and Quad Flow, or Storage Flow with a battery to charge without increasing your contracted power.
Industry and C&I
Businesses, hotels and shopping centres: City and Dual Totem Flow for AC, and Dual Wall or Dual Media Flow with a 43" advertising screen.
Safety and certifications
Rugged, protected and compliant.
The fast chargers declare conformity with the IEC 61851 series for conductive charging; the Dual Satellite Flow also with the IEC 61000-6 electromagnetic compatibility standards.
- 01
Outdoor enclosure
Carbon steel and IP55 across all fast chargers; IP54 to IP66 on AC and portable units.
- 02
Integrated AC protection
Type B RCD, MCB and surge protection on Dual Totem Flow posts; MID meter on City Flow.
- 03
Emergency stop
Emergency stop button and RFID cards on all DC fast chargers.
- 04
Safe high current
350 A air-cooled connectors (Dual Power Flow) and 500 A liquid-cooled connectors (Dual Hyper Flow).
Standards declared in the datasheet
IEC 61851-1
General requirements for conductive charging
IEC 61851-23
DC charging stations
IEC 61851-24
DC charger–vehicle communication (Dual Satellite Flow)
IEC 61851-21-2
Charger electromagnetic compatibility (Dual Satellite Flow)
IEC 61000-6-2 / -6-4
Immunity and emissions in industrial environments (Dual Satellite Flow)
OCPP 1.6J
Open charge point management protocol
Standards declared in the 2026 charger catalogue.
Planning to install fast charging?
Tell us how many vehicles, what power and what grid connection you have. We'll propose chargers, battery and connection, with the financial analysis.
